Flue Gas & Emission Monitoring

UV Flue Gas Analyzer

MH3200A UV flue gas analyzer for stack gas analysis, CEMS accuracy evaluation and calibration support.

MH3200AUV-DOASSO2NONO2NH3
UV Flue Gas Analyzer product series image for environmental monitoring projects
MediumStack gas, industrial exhaust, combustion flue gas or source emission points
ModeContinuous monitoring, source testing or inspection support depending on project scope
InstallationStack platform, analyzer cabinet, sampling line and data acquisition location
OutputLocal display, alarm output, communication interface or data acquisition discussion
Overview

UV Flue Gas Analyzer for environmental monitoring projects

MH3200A UV flue gas analyzer based on UV differential optical absorption spectroscopy for SO2, NO, NO2, NH3, CO, CO2 and oxygen-related flue gas applications.

MH3200A is selected for UV differential absorption spectroscopy analysis of flue gas SO2, NO, NO2, NH3, CO and CO2, with oxygen content measurement and CEMS accuracy evaluation support.

The instrument uses a hot-wet method: flue gas is extracted into a UV detection gas cell, with heated filter element, heated gas cell and heated path to vaporize moisture and reduce liquid water influence. The optical components use buffering and shock absorption for field use.

Product typeUV Flue Gas Analyzer
Measured itemsMH3200A / UV-DOAS / SO2 / NO / NO2 / NH3 / CO / CO2
Typical useStack gas component analysis / CEMS accuracy evaluation / Emission source testing
ConfigurationGas sampling, heated line, pretreatment, analyzer and condition sensors work together as one emission monitoring chain.
InstallationStack platform, analyzer cabinet, sampling line and data acquisition location
Data outputLocal display, alarm output, communication interface or data acquisition discussion
Detailed Parameters

Technical data for model selection

Review the main measuring range, output interface, operating conditions and configuration notes before quotation.

Selection Basis UV Flue Gas Analyzer

Huisheng confirms the final model, range and site configuration according to sample condition and monitoring requirement.

ItemSpecification / selection note
Analyzer routeAG-UVI13 UV-DOAS analyzer is listed in the CEMS gas-analysis subsystem
Typical measured gases in CEMS scopeSO2, NOx, CO, CO2, O2, HCl, HF and other project-specific gases depending on selected analyzer route
System positionInstalled as part of gas analysis cabinet with heated sampling, pretreatment and data acquisition
Sample routeHeated sampling probe, heated line, precision filtration and condenser pretreatment are described in the CEMS manual
Data interface contextCEMS system includes data acquisition/conversion module, IPC and system software
UV Flue Gas Analyzer application scene and monitoring workflow
Product RoleFlue Gas & Emission Monitoring
Working Logic

Configured around the actual monitoring point

Gas sampling, heated line, pretreatment, analyzer and condition sensors work together as one emission monitoring chain.

Monitoring point

Stack gas, industrial exhaust, combustion flue gas or source emission points

Sample condition

Temperature, moisture, dust, solids, corrosive components or compound type may affect configuration.

Instrument package

Analyzer, detector, sampler, cabinet, pretreatment and data output can be combined as one product package.

Model-specific specifications

Specifications are prepared according to the selected model and actual project requirement.

Product Details

Details Huisheng reviews before confirming a model

Huisheng reviews the product model together with the measured medium, target range, sampling condition, installation position and required specifications. This keeps the product discussion tied to the real monitoring point.

Measuring range

Expected concentration or detection level helps determine the model and measurement method.

Sample condition

Temperature, moisture, suspended solids, dust, corrosion or target compound behavior may change the configuration.

Method direction

Gas sampling, heated line, pretreatment, analyzer and condition sensors work together as one emission monitoring chain.

Installation package

Stack platform, analyzer cabinet, sampling line and data acquisition location

Data output

Communication output, alarm logic and model-specific specifications depend on the selected model.

Measured Parameters

Monitoring indicators covered by this product series

The final parameter package depends on the selected model, measuring range, sample condition and data output requirement. For many projects, one instrument is part of a complete monitoring point rather than a stand-alone purchase.

MH3200A

UV flue gas analysis item for hot-wet stack gas analysis and CEMS accuracy support.

UV-DOAS

UV flue gas analysis item for hot-wet stack gas analysis and CEMS accuracy support.

SO2

Stack gas indicator used for emission source monitoring and reporting.

NO

Stack gas indicator used for emission source monitoring and reporting.

NO2

Stack gas indicator used for emission source monitoring and reporting.

NH3

Gas indicator used for VOC, toxic gas, hazardous area or industrial boundary monitoring.

CO

Stack gas indicator used for emission source monitoring and reporting.

CO2

Stack gas indicator used for emission source monitoring and reporting.

O2

Stack gas indicator used for emission source monitoring and reporting.

System Composition

How the product fits into a complete monitoring chain

Most projects connect the product with sample access, conditioning, measurement, data acquisition and reporting. The exact arrangement depends on the site and selected model.

Heated sampling probe and filter

The sample access point determines whether filtration, heating, flow control or preservation is required.

Heated line and optical gas cell

This part is configured according to the selected model and actual site conditions.

UV differential absorption spectroscopy module

This part is configured according to the selected model and actual site conditions.

Oxygen / temperature / humidity support as configured

This part is configured according to the selected model and actual site conditions.

Display, data query and communication section

Data acquisition, alarm output and communication must match the project platform or reporting requirement.

UV Flue Gas Analyzer typical application site for environmental monitoring equipment
Application Scene Flue Gas & Emission Monitoring
Typical Applications

Where this equipment is usually discussed

Emission applications depend on the stack or duct condition. Gas temperature, dust load, moisture, sampling platform and reporting purpose all influence the analyzer, sampler or complete CEMS configuration.

Stack gas component analysis

Applied at fixed emission sources where sample extraction, condition measurement and reporting output must work as one chain.

CEMS accuracy evaluation

Configured according to the monitoring point, sample condition, installation environment and expected data use.

Emission source testing

Applied at fixed emission sources where sample extraction, condition measurement and reporting output must work as one chain.

Industrial flue gas inspection

Configured according to the monitoring point, sample condition, installation environment and expected data use.

Calibration support for monitoring systems

Configured according to the monitoring point, sample condition, installation environment and expected data use.