Water Quality Online Monitoring

UV Absorption Water Quality Monitor

AG-C08 UV absorption water quality monitor with RS485 Modbus RTU communication, IP68 protection and reagent-free fast measurement.

AG-C08UV absorptionCOD + turbidityIP68RS485 Modbus RTUReagent-free
UV Absorption Water Quality Monitor product series image for environmental monitoring projects
MediumWastewater, surface water, process water or water network points
ModeOnline, continuous or interval monitoring according to selected instrument and site condition
InstallationIndoor cabinet, outdoor station, shelter or process-side installation depending on site
OutputLocal display, alarm output, communication interface or data acquisition discussion
Overview

UV Absorption Water Quality Monitor for environmental monitoring projects

AG-C08 UV absorption water quality online monitor for COD and turbidity measurement in surface water, rivers, lakes, reservoirs, municipal wastewater, wastewater treatment and seawater monitoring.

AG-C08 is listed as a UV absorption online water quality monitor. It is relevant when a project needs fast sensor-based COD and turbidity trend measurement without wet-chemical reagents.

AG-C08 uses a UV absorption method with RS485 communication and Modbus RTU protocol. It can measure COD and turbidity at the same time, uses a corrosion-resistant stainless-steel body, supports self-cleaning, turbidity compensation and dual-beam measurement, and is suitable for surface water, river sections, lakes, reservoirs, municipal wastewater, wastewater treatment and seawater monitoring.

Product typeUV Absorption Water Quality Monitor
Measured itemsAG-C08 / UV absorption / COD + turbidity / IP68 / RS485 Modbus RTU / Reagent-free
Typical useRiver section monitoring / Lake and reservoir monitoring / Municipal wastewater trend monitoring
ConfigurationThe working method is confirmed according to selected model, monitored medium and project requirement.
InstallationIndoor cabinet, outdoor station, shelter or process-side installation depending on site
Data outputLocal display, alarm output, communication interface or data acquisition discussion
Detailed Parameters

Technical data for model selection

Review the main measuring range, output interface, operating conditions and configuration notes before quotation.

Selection Basis UV Absorption Water Quality Monitor

Huisheng confirms the final model, range and site configuration according to sample condition and monitoring requirement.

ItemSpecification / selection note
ModelAG-C08 UV absorption online water quality monitor
Measured parameterUltraviolet absorption; can measure COD and turbidity at the same time according to the product range
Working principleDual-wavelength UV method
Measuring range(0-200 / 1000) mg/L and (0-500) NTU
Measurement accuracy<10%
Resolution0.1 mg/L
Communication interfaceRS485, standard Modbus protocol
Electrode sizeD32 mm, L175 mm, 3 m cable; cable can be configured
Operating condition0-60 degrees C, 0-3 bar
Power12V / 24V DC, 0.4W
UV Absorption Water Quality Monitor application scene and monitoring workflow
Product RoleWater Quality Online Monitoring
Working Logic

Configured around the actual monitoring point

The working method is confirmed according to selected model, monitored medium and project requirement.

Monitoring point

Wastewater, surface water, process water or water network points

Sample condition

Temperature, moisture, dust, solids, corrosive components or compound type may affect configuration.

Instrument package

Analyzer, detector, sampler, cabinet, pretreatment and data output can be combined as one product package.

Model-specific specifications

Specifications are prepared according to the selected model and actual project requirement.

Product Details

Details Huisheng reviews before confirming a model

Huisheng reviews the product model together with the measured medium, target range, sampling condition, installation position and required specifications. This keeps the product discussion tied to the real monitoring point.

Measuring range

Expected concentration or detection level helps determine the model and measurement method.

Sample condition

Temperature, moisture, suspended solids, dust, corrosion or target compound behavior may change the configuration.

Method direction

The working method is confirmed according to selected model, monitored medium and project requirement.

Installation package

Indoor cabinet, outdoor station, shelter or process-side installation depending on site

Data output

Communication output, alarm logic and model-specific specifications depend on the selected model.

Measured Parameters

Monitoring indicators covered by this product series

The final parameter package depends on the selected model, measuring range, sample condition and data output requirement. For many projects, one instrument is part of a complete monitoring point rather than a stand-alone purchase.

AG-C08

This item is confirmed by the selected model, measuring range, sample condition and site requirement.

UV absorption

This item is confirmed by the selected model, measuring range, sample condition and site requirement.

COD + turbidity

This item is confirmed by the selected model, measuring range, sample condition and site requirement.

IP68

This item is confirmed by the selected model, measuring range, sample condition and site requirement.

RS485 Modbus RTU

This item is confirmed by the selected model, measuring range, sample condition and site requirement.

Reagent-free

This item is confirmed by the selected model, measuring range, sample condition and site requirement.

System Composition

How the product fits into a complete monitoring chain

Most projects connect the product with sample access, conditioning, measurement, data acquisition and reporting. The exact arrangement depends on the site and selected model.

UV optical measurement body

This part is configured according to the selected model and actual site conditions.

Self-cleaning structure

This part is configured according to the selected model and actual site conditions.

Turbidity compensation

This part is configured according to the selected model and actual site conditions.

RS485 Modbus RTU output

Data acquisition, alarm output and communication must match the project platform or reporting requirement.

Field mounting interface

This part is configured according to the selected model and actual site conditions.

UV Absorption Water Quality Monitor typical application site for environmental monitoring equipment
Application Scene Water Quality Online Monitoring
Typical Applications

Where this equipment is usually discussed

Water monitoring applications are selected by monitoring point first: discharge outlet, treatment process, river station, water network or industrial process water. The instrument scope then follows the parameter group, sample condition and cabinet arrangement.

River section monitoring

Suitable for distributed water points where physical, nutrient or chemical indicators need continuous observation.

Lake and reservoir monitoring

Configured according to the monitoring point, sample condition, installation environment and expected data use.

Municipal wastewater trend monitoring

Used where discharge quality, treatment stability or final outlet trends need to be followed with clearer online data.

Wastewater treatment monitoring

Used where discharge quality, treatment stability or final outlet trends need to be followed with clearer online data.

Seawater monitoring

Suitable for distributed water points where physical, nutrient or chemical indicators need continuous observation.