Water Quality Online Monitoring

COD Online Analyzer

AG-C07 CODcr online analyzer using dichromate digestion and color-change measurement for Chemical Oxygen Demand trend monitoring.

AG-C07CODcrHJ 377-2019 reference10-5000 mg/L configurableDichromate digestionAutomatic range switching
COD Online Analyzer product series image for environmental monitoring projects
MediumWastewater, surface water, process water or water network points
ModeOnline, continuous or interval monitoring according to selected instrument and site condition
InstallationIndoor cabinet, outdoor station, shelter or process-side installation depending on site
OutputLocal display, alarm output, communication interface or data acquisition discussion
Overview

COD Online Analyzer for environmental monitoring projects

AG-C07 CODcr online water quality analyzer for pollution-source wastewater, industrial process wastewater, municipal wastewater treatment plant effluent and surface water monitoring.

AG-C07 is selected for online CODcr monitoring at pollution-source outlets, industrial process wastewater points, industrial or municipal wastewater treatment plants and surface-water monitoring stations.

The working principle uses high-temperature digestion with potassium dichromate digestion solution, silver sulfate catalyst solution and concentrated sulfuric acid. After organic matter is oxidized, the instrument reads the color change and converts it into COD output. The available measuring range is 10-5000 mg/L and can be configured by project requirement.

Product typeCOD Online Analyzer
Measured itemsAG-C07 / CODcr / HJ 377-2019 reference / 10-5000 mg/L configurable / Dichromate digestion / Automatic range switching
Typical usePollution-source wastewater discharge / Industrial process wastewater / Municipal wastewater treatment plant monitoring
ConfigurationSample pretreatment, reaction or digestion and instrument measurement are configured around the actual sample condition.
InstallationIndoor cabinet, outdoor station, shelter or process-side installation depending on site
Data outputLocal display, alarm output, communication interface or data acquisition discussion
Detailed Parameters

Technical data for model selection

Review the main measuring range, output interface, operating conditions and configuration notes before quotation.

Selection Basis COD Online Analyzer

Huisheng confirms the final model, range and site configuration according to sample condition and monitoring requirement.

ItemSpecification / selection note
ModelAG-C07 CODcr online water quality analyzer
Method basisDichromate digestion / colorimetric measurement; HJ 828-2017 and HJ 377-2019 references
Measuring range10-5000 mg/L; range can be configured according to project requirement
Indication errorBelow 100 mg/L: <= +/-8%; above 100 mg/L: <= +/-5%; range points: 80% +/-5%, 50% +/-8%, 20% +/-10%
Repeatability<=5%
Measurement cycleMinimum 30 min; digestion time 10-30 min adjustable according to sample condition
Sampling cycleInterval measurement 20-9999 min adjustable; hourly mode available
Calibration / check cycle1-99 days adjustable
Output interfaceRS-232, RS-485 and 4-20mA
Power supplyAC220 +/-10% V, 50 +/-1 Hz, 5A
Operating environmentIndoor adjustable temperature; suggested 5-40 degrees C, humidity 45%-85%
Cabinet size1500(H) x 500(W) x 450(D) mm
COD Online Analyzer application scene and monitoring workflow
Product RoleWater Quality Online Monitoring
Working Logic

Configured around the actual monitoring point

Sample pretreatment, reaction or digestion and instrument measurement are configured around the actual sample condition.

Monitoring point

Wastewater, surface water, process water or water network points

Sample condition

Temperature, moisture, dust, solids, corrosive components or compound type may affect configuration.

Instrument package

Analyzer, detector, sampler, cabinet, pretreatment and data output can be combined as one product package.

Model-specific specifications

Specifications are prepared according to the selected model and actual project requirement.

Product Details

Details Huisheng reviews before confirming a model

Huisheng reviews the product model together with the measured medium, target range, sampling condition, installation position and required specifications. This keeps the product discussion tied to the real monitoring point.

Measuring range

Expected concentration or detection level helps determine the model and measurement method.

Sample condition

Temperature, moisture, suspended solids, dust, corrosion or target compound behavior may change the configuration.

Method direction

Sample pretreatment, reaction or digestion and instrument measurement are configured around the actual sample condition.

Installation package

Indoor cabinet, outdoor station, shelter or process-side installation depending on site

Data output

Communication output, alarm logic and model-specific specifications depend on the selected model.

Measured Parameters

Monitoring indicators covered by this product series

The final parameter package depends on the selected model, measuring range, sample condition and data output requirement. For many projects, one instrument is part of a complete monitoring point rather than a stand-alone purchase.

AG-C07

CODcr monitoring item used for organic pollution load, wastewater discharge and process trend review.

CODcr

CODcr monitoring item used for organic pollution load, wastewater discharge and process trend review.

HJ 377-2019 reference

This item is confirmed by the selected model, measuring range, sample condition and site requirement.

10-5000 mg/L configurable

CODcr monitoring item used for organic pollution load, wastewater discharge and process trend review.

Dichromate digestion

CODcr monitoring item used for organic pollution load, wastewater discharge and process trend review.

Automatic range switching

This item is confirmed by the selected model, measuring range, sample condition and site requirement.

System Composition

How the product fits into a complete monitoring chain

Most projects connect the product with sample access, conditioning, measurement, data acquisition and reporting. The exact arrangement depends on the site and selected model.

Sample intake and filtering path

The sample access point determines whether filtration, heating, flow control or preservation is required.

Potassium dichromate digestion solution

This part is configured according to the selected model and actual site conditions.

Silver sulfate catalyst and sulfuric acid reaction system

This part is configured according to the selected model and actual site conditions.

High-temperature digestion and colorimetric measurement

This part is configured according to the selected model and actual site conditions.

Automatic range and data output section

Data acquisition, alarm output and communication must match the project platform or reporting requirement.

COD Online Analyzer typical application site for environmental monitoring equipment
Application Scene Water Quality Online Monitoring
Typical Applications

Where this equipment is usually discussed

Water monitoring applications are selected by monitoring point first: discharge outlet, treatment process, river station, water network or industrial process water. The instrument scope then follows the parameter group, sample condition and cabinet arrangement.

Pollution-source wastewater discharge

Used where discharge quality, treatment stability or final outlet trends need to be followed with clearer online data.

Industrial process wastewater

Used where discharge quality, treatment stability or final outlet trends need to be followed with clearer online data.

Municipal wastewater treatment plant monitoring

Used where discharge quality, treatment stability or final outlet trends need to be followed with clearer online data.

Industrial wastewater treatment plant monitoring

Used where discharge quality, treatment stability or final outlet trends need to be followed with clearer online data.

Surface water quality observation

Suitable for distributed water points where physical, nutrient or chemical indicators need continuous observation.