Multi-Parameter Water Quality Monitoring System
AG-DC07 five-parameter monitor and AG-SZ071 sensor-method multi-parameter system for physical and electrochemical water quality indicators.
Multi-Parameter Water Quality Monitoring System for environmental monitoring projects
AG-DC07 five-parameter and AG-SZ071 multi-parameter water quality monitoring systems for sensor-based pH, turbidity, conductivity, dissolved oxygen and temperature monitoring.
AG-DC07 is used for five-parameter monitoring of pH, turbidity, conductivity, dissolved oxygen and temperature. AG-SZ071 is selected when a sensor-method multi-parameter system is needed for distributed or station-based water monitoring.
AG-DC07 and AG-SZ071 support sensor-method water monitoring for continuous physical and electrochemical trend data, including surface water, water networks, outdoor stations and process water monitoring.
Technical data for model selection
Review the main measuring range, output interface, operating conditions and configuration notes before quotation.
Huisheng confirms the final model, range and site configuration according to sample condition and monitoring requirement.
| Item | Specification / selection note |
|---|---|
| Model | AG-DC07 five-parameter online water quality monitor |
| Measured parameters | pH, turbidity, conductivity, dissolved oxygen and temperature |
| Display and data | 7-inch color touch screen; data storage, viewing and export functions; storage period can be set |
| Output function | RS485 Modbus RTU standard protocol; HJ212 national-station protocol optional |
| Temperature range / error | 0-55 degrees C; +/-0.5 degrees C |
| pH range / error | 0-14; +/-0.1 |
| Dissolved oxygen range / error | 0-20 mg/L; +/-3% |
| Turbidity range / error | 0-4000 NTU; +/-5% |
| Conductivity range / error | 0-20000 mS/m; +/-1% |
Configured around the actual monitoring point
Sensor-based monitoring can combine pH, ORP, DO, conductivity, turbidity and optional analyzer signals.
Wastewater, surface water, process water or water network points
Temperature, moisture, dust, solids, corrosive components or compound type may affect configuration.
Analyzer, detector, sampler, cabinet, pretreatment and data output can be combined as one product package.
Specifications are prepared according to the selected model and actual project requirement.
Details Huisheng reviews before confirming a model
Huisheng reviews the product model together with the measured medium, target range, sampling condition, installation position and required specifications. This keeps the product discussion tied to the real monitoring point.
Expected concentration or detection level helps determine the model and measurement method.
Temperature, moisture, suspended solids, dust, corrosion or target compound behavior may change the configuration.
Sensor-based monitoring can combine pH, ORP, DO, conductivity, turbidity and optional analyzer signals.
Indoor cabinet, outdoor station, shelter or process-side installation depending on site
Communication output, alarm logic and model-specific specifications depend on the selected model.
Monitoring indicators covered by this product series
The final parameter package depends on the selected model, measuring range, sample condition and data output requirement. For many projects, one instrument is part of a complete monitoring point rather than a stand-alone purchase.
AG-DC07
Sensor-method water-quality indicator used for continuous field trend monitoring and station integration.
AG-SZ071
Sensor-method water-quality indicator used for continuous field trend monitoring and station integration.
pH
Sensor-method water-quality indicator used for continuous field trend monitoring and station integration.
Turbidity
Sensor-method water-quality indicator used for continuous field trend monitoring and station integration.
Conductivity
Sensor-method water-quality indicator used for continuous field trend monitoring and station integration.
Dissolved oxygen
Sensor-method water-quality indicator used for continuous field trend monitoring and station integration.
Temperature
Sensor-method water-quality indicator used for continuous field trend monitoring and station integration.
Sensor method
This item is confirmed by the selected model, measuring range, sample condition and site requirement.
How the product fits into a complete monitoring chain
Most projects connect the product with sample access, conditioning, measurement, data acquisition and reporting. The exact arrangement depends on the site and selected model.
Sensor probes or flow cell
The sample access point determines whether filtration, heating, flow control or preservation is required.
pH / turbidity / conductivity / DO / temperature channels
This part is configured according to the selected model and actual site conditions.
Cleaning and calibration access
This part is configured according to the selected model and actual site conditions.
Controller and data logger
Data acquisition, alarm output and communication must match the project platform or reporting requirement.
Outdoor station or cabinet integration when required
This part is configured according to the selected model and actual site conditions.
Where this equipment is usually discussed
Water monitoring applications are selected by monitoring point first: discharge outlet, treatment process, river station, water network or industrial process water. The instrument scope then follows the parameter group, sample condition and cabinet arrangement.
Suitable for distributed water points where physical, nutrient or chemical indicators need continuous observation.
Suitable for distributed water points where physical, nutrient or chemical indicators need continuous observation.
Suitable for distributed water points where physical, nutrient or chemical indicators need continuous observation.
Suitable for distributed water points where physical, nutrient or chemical indicators need continuous observation.
Configured according to the monitoring point, sample condition, installation environment and expected data use.
Verified product photos for model review
Representative analyzer cabinets, model photos and configuration views from the water-quality product materials.
Products often discussed together
Environmental monitoring systems are often selected as a package. These related products may help complete the monitoring point.
Water Quality Online Monitoring
Outdoor Water Quality Monitoring Station
AG-SZ07 outdoor small-scale water quality monitoring station and AG-YG07 pipeline water quality monitor for field and network monitoring points.
View product
Water Quality Online Monitoring
Water Quality Online Analyzers
AG series online water quality analyzers, including CODcr, permanganate index, NH3-N, TP, TN, heavy metals, five-parameter systems, outdoor stations and pipeline water quality monitoring.
View product
Water Quality Online Monitoring
COD Online Analyzer
AG-C07 CODcr online water quality analyzer for pollution-source wastewater, industrial process wastewater, municipal wastewater treatment plant effluent and surface water monitoring.
View product
Water Quality Online Monitoring
Ammonia Nitrogen Online Analyzer
AG-N07 and AG-N08 ammonia nitrogen online water quality analyzers for pollution-source wastewater, municipal wastewater and surface water monitoring.
View product