RCO Catalytic Combustion Equipment
RCO treatment package combining activated carbon adsorption, thermal desorption and catalytic oxidation for VOC exhaust gas projects.
RCO Catalytic Combustion Equipment for pollution-control projects
Activated carbon adsorption-desorption plus catalytic combustion equipment for medium and high concentration VOC exhaust gas treatment in coating, printing, rubber, plastic and chemical applications.
RCO catalytic combustion equipment is discussed when a VOC project needs adsorption concentration, high-temperature desorption and catalytic oxidation rather than simple adsorption replacement.
Typical air-volume options from the new treatment document include 5000, 10000, 15000, 20000 and 30000 m3/h. The route uses honeycomb activated carbon for adsorption, hot-air desorption at about 160-180 deg C and a catalytic combustion chamber usually operating around 200-400 deg C.
Equipment data from supplied material
This table keeps the equipment values, routes and material options stated in the supplied product material. Selection notes and related-product links elsewhere on the page are website guidance, not added hard specifications.
Supplied RCO catalytic combustion standard parameter material. Final sizing still depends on site conditions, but the values in this table are kept to the supplied material.
| Item | Specification / selection note |
|---|---|
| Treatment route | Activated carbon adsorption-desorption plus catalytic combustion |
| Typical air volume | 5000 / 10000 / 15000 / 20000 / 30000 m3/h |
| Desorption hot air temperature | 160-180 deg C |
| Catalytic chamber reaction temperature | 200-400 deg C |
| Outlet temperature note | Normal exhaust outlet temperature is listed as below 80 deg C |
| Removal efficiency | VOCs overall removal efficiency is listed as >=95% |
| Main material options | Q235 carbon steel with high-temperature anticorrosion coating or 304 stainless steel for corrosive gas |
| Core consumables | Platinum-palladium honeycomb ceramic catalyst and honeycomb block activated carbon |
Configured around the actual treatment route
The treatment route is confirmed from the supplied equipment material, then sized by air volume, water volume, pollutant type, material requirement and site layout.
Project-specific wastewater, exhaust gas or pollution control applications
Air volume, water volume, pollutant type, temperature, humidity, corrosion and inlet condition affect configuration.
Treatment body, fans, ducts, pumps, control cabinet, safety protection and maintenance access are reviewed by route.
Hard parameters are kept to supplied product material; final sizing is confirmed by project condition.
Selection notes kept separate from source parameters
Huisheng reviews the treatment route, handled medium, capacity, material, outlet target and auxiliary systems before confirming a configuration. Documented values remain in the technical data table, while project pairing and monitoring-interface notes are treated as selection guidance.
Hard values are kept to the supplied product material. Project-specific sizing is treated as selection work, not as a new published parameter.
Exhaust gas, dust, odor, flue gas polishing or wastewater condition should be confirmed before choosing the treatment route.
Air volume, water volume, pollutant load and outlet requirement determine final equipment sizing.
Q235, 304 stainless steel, FRP, PP or anti-corrosion options are selected according to the documented material scope and site condition.
Fans, ducts, pumps, control cabinets, safety protection and monitoring interfaces are discussed as configuration notes.
Parameters and scope stated in supplied material
The items below summarize capacity, material, process route, efficiency or equipment-scope information from the supplied product material. Extra project advice stays in selection notes instead of becoming a published hard parameter.
5000-30000 m3/h
Documented RCO air-volume options for VOC exhaust gas treatment projects.
160-180 deg C desorption
Hot-air desorption temperature stated for activated carbon regeneration in the RCO route.
200-400 deg C catalytic chamber
Catalytic chamber reaction temperature used for VOC oxidation.
>=95% VOC removal
Overall VOC removal efficiency listed in the supplied RCO material.
PLC control
Automatic control cabinet used for desorption, temperature control and equipment protection.
Activated carbon + catalyst
Core adsorption and catalytic consumable route from the supplied RCO material.
How the equipment fits into a treatment route
Treatment equipment is configured by process route, pollutant type, air or water volume, material requirement and installation condition. Monitoring or sampling interfaces are considered only when the project needs them.
Dry filtration pretreatment box
This part is configured according to the selected model and actual site conditions.
Activated carbon adsorption boxes
This part is configured according to the selected model and actual site conditions.
Catalytic combustion chamber
This part is configured according to the selected model and actual site conditions.
Heat exchanger for heat recovery
This part is configured according to the selected model and actual site conditions.
PLC automatic control cabinet
This part is configured according to the selected model and actual site conditions.
Explosion relief and over-temperature protection
This part is configured according to the selected model and actual site conditions.
Where this equipment is usually discussed
This equipment is discussed when the project needs monitoring or supporting treatment equipment matched with the actual site, medium, parameter and reporting requirement.
Discussed as supporting equipment when pollution control and monitoring requirements are reviewed in the same project.
Discussed as supporting equipment when pollution control and monitoring requirements are reviewed in the same project.
Used around process areas, storage zones and boundary points where VOC or hazardous gas monitoring is required.
Discussed as supporting equipment when pollution control and monitoring requirements are reviewed in the same project.
Used around process areas, storage zones and boundary points where VOC or hazardous gas monitoring is required.
Products often discussed together
Environmental monitoring systems are often selected as a package. These related products may help complete the monitoring point.
Environmental Protection Equipment
VOC Exhaust Gas Treatment Equipment
Supplementary VOC exhaust gas treatment equipment, including UV-activated carbon, activated carbon adsorption, RCO and RTO systems.
View product
Environmental Protection Equipment
UV Photolysis Activated Carbon Equipment
Two-stage UV photolysis and activated carbon adsorption equipment for low-concentration VOC, odor and industrial exhaust gas treatment.
View product
Environmental Protection Equipment
Spray Scrubber Tower
Standard spray scrubber tower for paint mist, acid / alkaline exhaust, odor and smoke pretreatment before UV, RCO or dust-control equipment.
View product
VOC & Toxic Gas Detection
VOC Online Monitoring System
VOC, NMHC and benzene series online monitoring system for industrial emission sources and ambient applications.
View product