Water Quality Online Monitoring

Permanganate Index Online Analyzer

AG-CMn07 online analyzer for permanganate index monitoring in surface water and environmental water quality projects.

AG-CMn07CODmnHJ/T100-2003 reference0-20 mg/L configurablePotassium permanganate oxidationSurface water
Permanganate Index Online Analyzer product series image for environmental monitoring projects
MediumWastewater, surface water, process water or water network points
ModeOnline, continuous or interval monitoring according to selected instrument and site condition
InstallationIndoor cabinet, outdoor station, shelter or process-side installation depending on site
OutputLocal display, alarm output, communication interface or data acquisition discussion
Overview

Permanganate Index Online Analyzer for environmental monitoring projects

AG-CMn07 permanganate index online water quality analyzer for surface water monitoring, using potassium permanganate oxidation spectrophotometry.

AG-CMn07 is used for online permanganate index monitoring, especially in surface-water and water-source projects where CODmn is used as an organic pollution trend indicator.

The measurement route uses potassium permanganate oxidation spectrophotometry. Potassium permanganate and sulfuric acid are added to the sample, the mixture is digested, and the instrument converts the color change into permanganate index output. The available measuring range is 0-20 mg/L and can be configured by project requirement.

Product typePermanganate Index Online Analyzer
Measured itemsAG-CMn07 / CODmn / HJ/T100-2003 reference / 0-20 mg/L configurable / Potassium permanganate oxidation / Surface water
Typical useSurface water monitoring / River and lake water quality observation / Environmental monitoring stations
ConfigurationThe working method is confirmed according to selected model, monitored medium and project requirement.
InstallationIndoor cabinet, outdoor station, shelter or process-side installation depending on site
Data outputLocal display, alarm output, communication interface or data acquisition discussion
Detailed Parameters

Technical data for model selection

Review the main measuring range, output interface, operating conditions and configuration notes before quotation.

Selection Basis Permanganate Index Online Analyzer

Huisheng confirms the final model, range and site configuration according to sample condition and monitoring requirement.

ItemSpecification / selection note
ModelAG-CMn07 permanganate index online water quality analyzer
Measurement methodPotassium permanganate oxidation spectrophotometry
Measuring range0-20 mg/L; range can be configured
Repeatability+/-5%
Zero drift+/-5%
Range drift+/-5%
Output interfaceRS232, RS485 and 4-20mA
Permanganate Index Online Analyzer application scene and monitoring workflow
Product RoleWater Quality Online Monitoring
Working Logic

Configured around the actual monitoring point

The working method is confirmed according to selected model, monitored medium and project requirement.

Monitoring point

Wastewater, surface water, process water or water network points

Sample condition

Temperature, moisture, dust, solids, corrosive components or compound type may affect configuration.

Instrument package

Analyzer, detector, sampler, cabinet, pretreatment and data output can be combined as one product package.

Model-specific specifications

Specifications are prepared according to the selected model and actual project requirement.

Product Details

Details Huisheng reviews before confirming a model

Huisheng reviews the product model together with the measured medium, target range, sampling condition, installation position and required specifications. This keeps the product discussion tied to the real monitoring point.

Measuring range

Expected concentration or detection level helps determine the model and measurement method.

Sample condition

Temperature, moisture, suspended solids, dust, corrosion or target compound behavior may change the configuration.

Method direction

The working method is confirmed according to selected model, monitored medium and project requirement.

Installation package

Indoor cabinet, outdoor station, shelter or process-side installation depending on site

Data output

Communication output, alarm logic and model-specific specifications depend on the selected model.

Measured Parameters

Monitoring indicators covered by this product series

The final parameter package depends on the selected model, measuring range, sample condition and data output requirement. For many projects, one instrument is part of a complete monitoring point rather than a stand-alone purchase.

AG-CMn07

Permanganate index monitoring item used for surface water and organic pollution trend observation.

CODmn

Permanganate index monitoring item used for surface water and organic pollution trend observation.

HJ/T100-2003 reference

This item is confirmed by the selected model, measuring range, sample condition and site requirement.

0-20 mg/L configurable

This item is confirmed by the selected model, measuring range, sample condition and site requirement.

Potassium permanganate oxidation

This item is confirmed by the selected model, measuring range, sample condition and site requirement.

Surface water

This item is confirmed by the selected model, measuring range, sample condition and site requirement.

System Composition

How the product fits into a complete monitoring chain

Most projects connect the product with sample access, conditioning, measurement, data acquisition and reporting. The exact arrangement depends on the site and selected model.

Water sample intake

This part is configured according to the selected model and actual site conditions.

Potassium permanganate and sulfuric acid reaction

This part is configured according to the selected model and actual site conditions.

Digestion and colorimetric measurement

This part is configured according to the selected model and actual site conditions.

Automatic cleaning and range management

This part is configured according to the selected model and actual site conditions.

RS232 / RS485 / 4-20mA output

Data acquisition, alarm output and communication must match the project platform or reporting requirement.

Permanganate Index Online Analyzer typical application site for environmental monitoring equipment
Application Scene Water Quality Online Monitoring
Typical Applications

Where this equipment is usually discussed

Water monitoring applications are selected by monitoring point first: discharge outlet, treatment process, river station, water network or industrial process water. The instrument scope then follows the parameter group, sample condition and cabinet arrangement.

Surface water monitoring

Suitable for distributed water points where physical, nutrient or chemical indicators need continuous observation.

River and lake water quality observation

Suitable for distributed water points where physical, nutrient or chemical indicators need continuous observation.

Environmental monitoring stations

Configured according to the monitoring point, sample condition, installation environment and expected data use.

Water-source trend monitoring

Suitable for distributed water points where physical, nutrient or chemical indicators need continuous observation.