Water Quality Online Monitoring

Ammonia Nitrogen Online Analyzer

AG-N07 / AG-N08 NH3-N online analyzers for wastewater and surface-water ammonia nitrogen monitoring.

AG-N07AG-N08NH3-NHJ 101-2019 reference0-300 mg/L configurableAutomatic range switching
Ammonia Nitrogen Online Analyzer product series image for environmental monitoring projects
MediumWastewater, surface water, process water or water network points
ModeOnline, continuous or interval monitoring according to selected instrument and site condition
InstallationIndoor cabinet, outdoor station, shelter or process-side installation depending on site
OutputLocal display, alarm output, communication interface or data acquisition discussion
Overview

Ammonia Nitrogen Online Analyzer for environmental monitoring projects

AG-N07 and AG-N08 ammonia nitrogen online water quality analyzers for pollution-source wastewater, municipal wastewater and surface water monitoring.

AG-N07 and AG-N08 are selected for online ammonia nitrogen monitoring at pollution-source outlets, municipal wastewater treatment plants, industrial wastewater points and surface-water monitoring stations.

The NH3-N analyzer supports a configurable 0-300 mg/L measuring range and can be set up for long-term unattended operation according to site requirements. Model selection should confirm sample turbidity, expected concentration, cleaning routine and reporting interface.

Product typeAmmonia Nitrogen Online Analyzer
Measured itemsAG-N07 / AG-N08 / NH3-N / HJ 101-2019 reference / 0-300 mg/L configurable / Automatic range switching
Typical useMunicipal wastewater treatment plants / Pollution-source wastewater discharge / Surface water monitoring
ConfigurationNH3-N measurement method, pH influence and temperature condition are matched with the monitoring site.
InstallationIndoor cabinet, outdoor station, shelter or process-side installation depending on site
Data outputLocal display, alarm output, communication interface or data acquisition discussion
Detailed Parameters

Technical data for model selection

Review the main measuring range, output interface, operating conditions and configuration notes before quotation.

Selection Basis Ammonia Nitrogen Online Analyzer

Huisheng confirms the final model, range and site configuration according to sample condition and monitoring requirement.

ItemSpecification / selection note
ModelsAG-N07 and AG-N08 ammonia nitrogen online water quality analyzers
Standard referenceHJ 101-2019 ammonia nitrogen online water quality analyzer requirement and test method
Measuring range0-300 mg/L; range can be configured
Indication error80% range +/-3%, 50% range +/-5%, 20% range +/-8%
Repeatability<=2%
24h low-concentration drift<=0.02 mg/L
24h high-concentration drift<=1%
Output interfaceRS232, RS485 and 4-20mA
Function notesMultiple measuring ranges, automatic switching, remote monitoring and remote operation command support are available
Ammonia Nitrogen Online Analyzer application scene and monitoring workflow
Product RoleWater Quality Online Monitoring
Working Logic

Configured around the actual monitoring point

NH3-N measurement method, pH influence and temperature condition are matched with the monitoring site.

Monitoring point

Wastewater, surface water, process water or water network points

Sample condition

Temperature, moisture, dust, solids, corrosive components or compound type may affect configuration.

Instrument package

Analyzer, detector, sampler, cabinet, pretreatment and data output can be combined as one product package.

Model-specific specifications

Specifications are prepared according to the selected model and actual project requirement.

Product Details

Details Huisheng reviews before confirming a model

Huisheng reviews the product model together with the measured medium, target range, sampling condition, installation position and required specifications. This keeps the product discussion tied to the real monitoring point.

Measuring range

Expected concentration or detection level helps determine the model and measurement method.

Sample condition

Temperature, moisture, suspended solids, dust, corrosion or target compound behavior may change the configuration.

Method direction

NH3-N measurement method, pH influence and temperature condition are matched with the monitoring site.

Installation package

Indoor cabinet, outdoor station, shelter or process-side installation depending on site

Data output

Communication output, alarm logic and model-specific specifications depend on the selected model.

Measured Parameters

Monitoring indicators covered by this product series

The final parameter package depends on the selected model, measuring range, sample condition and data output requirement. For many projects, one instrument is part of a complete monitoring point rather than a stand-alone purchase.

AG-N07

Ammonia nitrogen monitoring item used for wastewater nitrogen control and surface-water monitoring.

AG-N08

Ammonia nitrogen monitoring item used for wastewater nitrogen control and surface-water monitoring.

NH3-N

Ammonia nitrogen monitoring item used for wastewater nitrogen control and surface-water monitoring.

HJ 101-2019 reference

This item is confirmed by the selected model, measuring range, sample condition and site requirement.

0-300 mg/L configurable

Ammonia nitrogen monitoring item used for wastewater nitrogen control and surface-water monitoring.

Automatic range switching

Ammonia nitrogen monitoring item used for wastewater nitrogen control and surface-water monitoring.

System Composition

How the product fits into a complete monitoring chain

Most projects connect the product with sample access, conditioning, measurement, data acquisition and reporting. The exact arrangement depends on the site and selected model.

Sample intake and pretreatment

The sample access point determines whether filtration, heating, flow control or preservation is required.

NH3-N analysis module

This part is configured according to the selected model and actual site conditions.

Reagent / reaction or detection section

This part is configured according to the selected model and actual site conditions.

Automatic range and calibration arrangement

This part is configured according to the selected model and actual site conditions.

Controller and data output

Data acquisition, alarm output and communication must match the project platform or reporting requirement.

Ammonia Nitrogen Online Analyzer typical application site for environmental monitoring equipment
Application Scene Water Quality Online Monitoring
Typical Applications

Where this equipment is usually discussed

Water monitoring applications are selected by monitoring point first: discharge outlet, treatment process, river station, water network or industrial process water. The instrument scope then follows the parameter group, sample condition and cabinet arrangement.

Municipal wastewater treatment plants

Used where discharge quality, treatment stability or final outlet trends need to be followed with clearer online data.

Pollution-source wastewater discharge

Used where discharge quality, treatment stability or final outlet trends need to be followed with clearer online data.

Surface water monitoring

Suitable for distributed water points where physical, nutrient or chemical indicators need continuous observation.

Industrial wastewater monitoring

Used where discharge quality, treatment stability or final outlet trends need to be followed with clearer online data.

Nutrient control projects

Configured according to the monitoring point, sample condition, installation environment and expected data use.