Heavy Metal Online Analyzer
AG-series parameter-specific heavy metal and toxic indicator online analyzers selected according to target element and measuring range.
Heavy Metal Online Analyzer for environmental monitoring projects
AG heavy metal online analyzers for hexavalent chromium, lead, cadmium, arsenic, total chromium, zinc, nickel, iron, manganese, copper, silver, cyanide, cobalt, antimony and tin monitoring.
Heavy metal monitoring is selected by target element rather than one universal analyzer. The AG scope includes hexavalent chromium, lead, cadmium, arsenic, total chromium, zinc, nickel, iron, volatile phenol, manganese, copper, fluoride ion (F-), silver, cyanide, cobalt, antimony, tin, thallium and mercury.
The heavy-metal range is selected by target indicator and sample matrix. Typical examples include 0-20 mg/L for several metal indicators, 0-10 mg/L for selected toxic indicators and 0-2 mg/L for cadmium. Final selection depends on target element, expected concentration and wastewater condition.
Technical data for model selection
Review the main measuring range, output interface, operating conditions and configuration notes before quotation.
Huisheng confirms the final model, range and site configuration according to sample condition and monitoring requirement.
| Item | Specification / selection note |
|---|---|
| Indicator scope | Hexavalent chromium, lead, cadmium, arsenic, total chromium, zinc, nickel, iron, manganese, copper, silver, cyanide, cobalt, antimony, tin, thallium and mercury can be selected by project requirement |
| Hexavalent chromium example | 0-20 mg/L configurable; indication error +/-8%; zero drift <=5%; range drift <=5%; output RS232 / RS485 / 4-20mA |
| Lead example | 0-10 mg/L configurable; indication error +/-5%; zero drift +/-5%; range drift +/-10%; output RS232 / RS485 / 4-20mA |
| Cadmium example | 0-2 mg/L configurable; indication error +/-5%; zero drift +/-5%; range drift +/-10%; output RS232 / RS485 / 4-20mA |
| Arsenic example | 0-20 mg/L configurable; indication error +/-5%; zero drift +/-5%; range drift +/-10%; output RS232 / RS485 / 4-20mA |
| Total chromium example | 0-20 mg/L configurable; indication error +/-5%; zero drift +/-5% of range; range drift +/-5% of range |
| Selection note from product structure | The analyzer is selected by the exact target element and expected concentration range, not as one universal heavy-metal model |
Configured around the actual monitoring point
The target element, detection limit and pretreatment route must be confirmed parameter by parameter.
Wastewater, surface water, process water or water network points
Temperature, moisture, dust, solids, corrosive components or compound type may affect configuration.
Analyzer, detector, sampler, cabinet, pretreatment and data output can be combined as one product package.
Specifications are prepared according to the selected model and actual project requirement.
Details Huisheng reviews before confirming a model
Huisheng reviews the product model together with the measured medium, target range, sampling condition, installation position and required specifications. This keeps the product discussion tied to the real monitoring point.
Expected concentration or detection level helps determine the model and measurement method.
Temperature, moisture, suspended solids, dust, corrosion or target compound behavior may change the configuration.
The target element, detection limit and pretreatment route must be confirmed parameter by parameter.
Indoor cabinet, outdoor station, shelter or process-side installation depending on site
Communication output, alarm logic and model-specific specifications depend on the selected model.
Monitoring indicators covered by this product series
The final parameter package depends on the selected model, measuring range, sample condition and data output requirement. For many projects, one instrument is part of a complete monitoring point rather than a stand-alone purchase.
AG-Cr6+07
Parameter-specific analyzer selected by target metal, measuring range and wastewater matrix.
AG-TPb07
Parameter-specific analyzer selected by target metal, measuring range and wastewater matrix.
AG-TCd07
Parameter-specific analyzer selected by target metal, measuring range and wastewater matrix.
AG-TAS07
Parameter-specific analyzer selected by target metal, measuring range and wastewater matrix.
AG-TCr07
Parameter-specific analyzer selected by target metal, measuring range and wastewater matrix.
AG-TZn07
Parameter-specific analyzer selected by target metal, measuring range and wastewater matrix.
AG-TNi07
Parameter-specific analyzer selected by target metal, measuring range and wastewater matrix.
AG-TCu07
Parameter-specific analyzer selected by target metal, measuring range and wastewater matrix.
AG-TCN07
Parameter-specific analyzer selected by target metal, measuring range and wastewater matrix.
AG-TI07
Parameter-specific analyzer selected by target metal, measuring range and wastewater matrix.
AG-THg07
Parameter-specific analyzer selected by target metal, measuring range and wastewater matrix.
How the product fits into a complete monitoring chain
Most projects connect the product with sample access, conditioning, measurement, data acquisition and reporting. The exact arrangement depends on the site and selected model.
Parameter-specific AG analyzer model
This part is configured according to the selected model and actual site conditions.
Sample pathway compatible with target indicator
The sample access point determines whether filtration, heating, flow control or preservation is required.
Pretreatment / digestion or reaction section
Pretreatment protects the analyzer and helps keep measurement conditions stable.
Reagent and calibration arrangement
This part is configured according to the selected model and actual site conditions.
Data output and waste handling
Data acquisition, alarm output and communication must match the project platform or reporting requirement.
Where this equipment is usually discussed
Water monitoring applications are selected by monitoring point first: discharge outlet, treatment process, river station, water network or industrial process water. The instrument scope then follows the parameter group, sample condition and cabinet arrangement.
Used where discharge quality, treatment stability or final outlet trends need to be followed with clearer online data.
Used where discharge quality, treatment stability or final outlet trends need to be followed with clearer online data.
Configured according to the monitoring point, sample condition, installation environment and expected data use.
Used where discharge quality, treatment stability or final outlet trends need to be followed with clearer online data.
Suitable for distributed water points where physical, nutrient or chemical indicators need continuous observation.
Configured according to the monitoring point, sample condition, installation environment and expected data use.
Verified product photos for model review
Representative analyzer cabinets, model photos and configuration views from the water-quality product materials.
Products often discussed together
Environmental monitoring systems are often selected as a package. These related products may help complete the monitoring point.
Water Quality Online Monitoring
Water Quality Online Analyzers
AG series online water quality analyzers, including CODcr, permanganate index, NH3-N, TP, TN, heavy metals, five-parameter systems, outdoor stations and pipeline water quality monitoring.
View product
Water Quality Online Monitoring
COD Online Analyzer
AG-C07 CODcr online water quality analyzer for pollution-source wastewater, industrial process wastewater, municipal wastewater treatment plant effluent and surface water monitoring.
View product
Water Quality Online Monitoring
Multi-Parameter Water Quality Monitoring System
AG-DC07 five-parameter and AG-SZ071 multi-parameter water quality monitoring systems for sensor-based pH, turbidity, conductivity, dissolved oxygen and temperature monitoring.
View product
Water Quality Online Monitoring
Outdoor Water Quality Monitoring Station
AG-SZ07 outdoor small-scale water quality monitoring station and AG-YG07 pipeline water quality monitor for field and network monitoring points.
View product