Vacuum Box Sampler
MH3051 vacuum box sampler using negative-pressure intake principle for gas bag VOC sampling and field monitoring.
Vacuum Box Sampler for environmental monitoring projects
MH3051 vacuum box sampler for vacuum-assisted gas bag sampling of fixed pollution source VOC emissions and negative-pressure flue gas sampling scenarios.
MH3051 is a vacuum box sampler using negative-pressure intake. It is intended for fixed pollution source VOC emission sampling and monitoring, research institute sampling analysis and other gas bag sampling occasions, especially negative-pressure flue gas scenarios.
The product supports vacuum box pressure range from -13 kPa to +5 kPa. The sampling interface supports gas bag volume settings, with examples of 1 L and 3 L gas bag timing. It references HJ732-2014 for fixed pollution source waste gas VOC bag sampling.
Technical data for model selection
Review the main measuring range, output interface, operating conditions and configuration notes before quotation.
Huisheng confirms the final model, range and site configuration according to sample condition and monitoring requirement.
| Item | Specification / selection note |
|---|---|
| Product direction | Vacuum box sampler for VOC canister sampling support |
| Sampling context | Ambient or source VOC sample collection where canister filling method is required |
| Selection basis | Canister specification, target compounds, sampling flow and field method |
| Connected products | VOC sampler, gas chromatograph and GC-MS laboratory analysis |
Configured around the actual monitoring point
Sampling method, container, flow stability and preservation condition determine the equipment package.
Flue gas, VOC, ambient air or field sampling media
Temperature, moisture, dust, solids, corrosive components or compound type may affect configuration.
Analyzer, detector, sampler, cabinet, pretreatment and data output can be combined as one product package.
Specifications are prepared according to the selected model and actual project requirement.
Details Huisheng reviews before confirming a model
Huisheng reviews the product model together with the measured medium, target range, sampling condition, installation position and required specifications. This keeps the product discussion tied to the real monitoring point.
Canister, adsorption tube, stack gas, particulate or other field sampling methods are matched with the application.
Sampling flow, duration, volume and stability are matched with the required procedure.
Canister, adsorption tube, filter holder, absorption bottle or sample container requirements are matched with the sampling method.
Field sampling setup with pump, line, container, flow control or tripod/enclosure
Sampling record, storage condition and laboratory follow-up requirements are included in the discussion.
Monitoring indicators covered by this product series
The final parameter package depends on the selected model, measuring range, sample condition and data output requirement. For many projects, one instrument is part of a complete monitoring point rather than a stand-alone purchase.
MH3051
Vacuum-box sampling item for gas-bag VOC collection and negative-pressure sampling conditions.
Vacuum box
Vacuum-box sampling item for gas-bag VOC collection and negative-pressure sampling conditions.
Gas bag method
Vacuum-box sampling item for gas-bag VOC collection and negative-pressure sampling conditions.
-13 to +5 kPa
Vacuum-box sampling item for gas-bag VOC collection and negative-pressure sampling conditions.
1-3 L gas bag
Vacuum-box sampling item for gas-bag VOC collection and negative-pressure sampling conditions.
Fixed source VOCs
This item is confirmed by the selected model, measuring range, sample condition and site requirement.
How the product fits into a complete monitoring chain
Most projects connect the product with sample access, conditioning, measurement, data acquisition and reporting. The exact arrangement depends on the site and selected model.
Vacuum box main unit
Huisheng matches field sampling details with the required method, container and laboratory follow-up plan.
External sampling gun
Huisheng matches field sampling details with the required method, container and laboratory follow-up plan.
Sampling gun adapter
The sample access point determines whether filtration, heating, flow control or preservation is required.
Gas bag connection
Huisheng matches field sampling details with the required method, container and laboratory follow-up plan.
Cleaning, timing and sampling program
Huisheng matches field sampling details with the required method, container and laboratory follow-up plan.
Where this equipment is usually discussed
Sampling applications start from the required method and sample path. Flow stability, container type, sampling duration, preservation condition and laboratory follow-up define the equipment package.
Selected when representative field collection, controlled flow and later analysis are part of the monitoring method.
Selected when representative field collection, controlled flow and later analysis are part of the monitoring method.
Configured according to the monitoring point, sample condition, installation environment and expected data use.
Supports controlled sample analysis, verification testing and quality control after field monitoring or sampling.
Applied at fixed emission sources where sample extraction, condition measurement and reporting output must work as one chain.
Products often discussed together
Environmental monitoring systems are often selected as a package. These related products may help complete the monitoring point.
Environmental Sampling Equipment
VOC Sampler
MH3050 pollution-source VOCs sampler using solid adsorption method for fixed pollution source VOC emission sampling and monitoring.
View product
Environmental Sampling Equipment
Ambient Air Particle Sampler
MH1205 constant-temperature constant-flow ambient air / particulate sampler for toxic gases, TSP, PM10, PM2.5, airborne metals, airborne fluoride compounds and SVOCs sampling.
View product
Environmental Sampling Equipment
Automatic Flue Gas Sampler
MH3001 automatic flue gas sampler for fixed pollution source gaseous pollutant sampling with two-channel constant-flow control.
View product
Laboratory Instruments
Laboratory Analysis Instruments
Supporting laboratory instruments for environmental testing, including UV-visible spectrophotometer, atomic absorption, atomic fluorescence, GC, HPLC, GC-MS, XRD and laboratory support equipment.
View product